• UHV-40A Transformer DC Winding Resistance Tester

    Compact & lightweight design. Intuitive Chinese menu operation.Rapid measurements with lab-grade accuracy.

    Product Details of UHV-40A Transformer DC Winding Resistance Tester

    Product Introduction

    Transformer DC Winding Resistance Tester using new power technology, with characteristics such as stable performance, rapid test, small size, light weight, easy operation, high measure precision and good data reproducibility, is the ideal equipment to measure transformer winding and DC resistance of high-power inductive device.

    This product complies with DL/T845.3-2004, national standards GB6587 "Environmental test general program of electronic measuring instruments" and GB6593 "Quality inspection provisions for electronic measuring instruments".


    المعايير الفنية

    اختبار الحالي2.5A 5A 10A 20A 40A
    يتراوح2.5A:10mΩ~8Ω
    5A:1mΩ~4Ω
    10A:1mΩ~2Ω
    20A:1mΩ~1Ω
    40A:1mΩ~500mΩ
    دقة القياس± (0.2% full scale ±2 words)
    مخزن البيانات255
    عرضLCD, resistance display is 4 1/2 bits
    Maximum resolution0.1mΩ
    قوةAC 220V±22V, 50Hz± 2Hz, safety tube 10A
    Maximum power consumption1200W, when the test current is 40A
    بيئة العملAmbient temperature:0° to 40°
    Relative humidity:≤80%
    مقدار440╳230╳490(mm)
    وزن20kg without accessories


    مواصفات المنتج

    1. Compact in size and lightweight.

    2. Full English menu operation, easy and convenient to operate.

    3. Fast measurement speed, accurate and stable data.

    4. Equipped with automatic discharge and discharge indication functions, reducing misoperation and ensuring equipment and personnel safety.


    Precautions

    ① After measuring the inductive load, the test line cannot be directly removed to avoid endangering the safety of testing personnel and equipment due to inductive discharge. The output terminal of this machine is equipped with a discharge circuit. When the output is turned off, the inductor will release energy through the instrument. The test line can only be removed after the discharge indicator is completed.

    ② For no-load tap changers, it is not allowed to switch tap changers during the measurement process.

    ③ If the power suddenly shuts down during the measurement process, this machine will automatically start discharging. Please do not immediately remove the wiring, wait at least 30 seconds before removing the wiring.

    ④ When measuring, do not short-circuit other untested windings to ground, otherwise it will slow down the transformer magnetization process and prolong the data stability time.

    ⑤ Please check the power supply voltage before starting up: AC 220V ± 10% 50Hz.

    ⑥ Please confirm that the tested equipment has been powered off and disconnected from other live devices during the experiment.

    ⑦ The casing must be reliably grounded during the experiment.

    ⑧ During the experiment, unrelated items are not allowed to be stacked on or around the equipment panel.

    ⑨ When replacing the fuse and accessories, please use the same model as this instrument.

    ⑩ This instrument should be moisture-proof and oil proof








    قد يعجبك ايضا

    • لديك أي أسئلة!

      لا تتردد في الاتصال بنا في أي وقت
      اتصل بنا
    • زورنا

      المبنى رقم 6، مجمع أوبتكس فالي الصناعي البصري الميكانيكي، 84 طريق جاوكسين 5،
      منطقة تطوير التكنولوجيا الجديدة في البحيرة الشرقية، مدينة ووهان، مقاطعة هوبي، الصين

    • ارسل لنا عبر البريد الإلكتروني

      تشياو@hvtest.cc

    • اتصل بنا

      +86-15871365102