Product Introduction
Intelligent instrument calibrator for PT CT error and impedance admittance test.It meets the requirements of JJG313-94 current transformer verification regulation and JJG314-94 voltage transformer verification regulation.
Product Characteristics
1、Intelligent transformer calibrator adopts 320 240 lattice liquid crystal, with large visual range and long life backlight, convenient to use
2、Chinese operation interface, beautiful interface
3、The percentage difference Angle difference is displayed in large font, which is convenient for users to observe
4、The intelligent transformer calibrator produced by our company fully meets the requirements of jjg314-1993 and jjg314-1994, and it can be sampled automatically
5、Automatically judge polarity error, change ratio error
6、The upper computer software has the open function of virtual instrument
7、Completely solve the s-level measurement problem
8、Automatic range switching
9、The perfect combination of advanced and unique circuit and DSP technology can completely remove the problem of the circuit instability
10、power dissipation:<15VA(No micro printer);<25VA(microprinter)
11、Harmonic suppression ratio:>40db
12、boundary dimension(Band dimensions):260×350×150mm3
13、weight:6kg
المعايير الفنية
| بيئة تشغيل المعدات | temperature:5℃~40℃ | relative humidity:<80%(25℃) |
| altitude:<2500m | ||
| mains frequency:50Hz±0.5Hz | mains input:220V±5V | |
| نطاق القياس | cophase component(%):0.0001~200.0 | distinguishability:0.0001 |
| orthogonal component(part):0.001~700.0 | distinguishability:0.001 | |
| impedance(Ω):0.0001~20.0 | distinguishability:0.0001 | |
| admittance(ms):0.0001~20.0 | distinguishability:0.0001 | |
| خطأ جوهري | مكون الطور المشترك | ΔX=±(X×2%+Y×2%)±Dx(Level 1 is optional) |
| مكون متعامد | ΔY=±(X×2%+Y×2%)±Dy(Level 1 is optional) | |
| "X"、"Y"——Display value of instrument | ||
| "Dx,Dy"——Display value of instrument | ||
| Dx=2,Dy=5 | ||
| اطلب مؤشر | PETS2 (المستوى 1 اختياري) | |
| معدل العمل | كهرباء | (1%~149%)In (In =5A) |
| (5%~149%)In (In =1A) | ||
| الجهد االكهربى | (5%~149%)Un (Un =100V,150V,100V/) | |
| (5%~149%)Un (Un =100V/3) | ||
| عبء العمل | كهرباء | TO to TX<0.12Ω cosΦ=1 |
| الجهد االكهربى | a to x<0.25VA (100V) | |
| إشارة خطأ قطبية | عندما يصل تيار التشغيل (الجهد) إلى أكثر من 5% من التيار المقنن (الجهد) ويتجاوز الخطأ 180%، يجب أن يكون هناك مؤشر قطبية. | |
| ملحوظة: إذا كان أكثر من 10% من تيار التشغيل المقدر (الجهد)، فلا يوجد حتى الآن مؤشر قطبية مناسب، مما يشير إلى وجود خطأ. يرجى عدم زيادة التيار (الجهد) لتجنب حرق الجهاز. | ||
| إشارة خطأ نسبة متغيرة | عندما يصل تيار التشغيل (الجهد) إلى أكثر من 5% من التيار المقنن (الجهد) ويتجاوز الخطأ 30% ولكنه أقل من 180%، يجب إعطاء إشارة الخطأ لنسبة متغيرة. | |
| اختبار العزل والجهد و تعليمات | محطةTX( | |
| The power socket can withstand the housing1.5kV,1minwithstand voltage | ||