    يقوم نظام اختبار الرنين AC بتردد الطاقة القابل للتعديل من سلسلة UHV (L) بإجراء اختبار تحمل الجهد بشكل أساسي لمولد هيدروليكي بقدرة 250 ميجاوات أو أصغر وأدوات كهربائية أخرى وما إلى ذلك. ويتكون النظام بشكل أساسي من مصدر طاقة التيار المتردد، منظم الجهد، محول الإثارة، عالي مفاعلات الجهد، مقسم الجهد العالي الخ.

    تفاصيل المنتج لنظام اختبار الرنين AC بتردد الطاقة القابل للتعديل UHV (L).


    UHV(L) Power Frequency Series Resonant System

    23

    The UHV(L) Power Frequency Series Resonant Test System is designed for AC withstand tests on single hydro-generators with a capacity of 250MW or less. This system delivers an output voltage waveform with a distortion rate (THD) superior to all existing AC withstand voltage devices, effectively preventing flashover or breakdown and automatically extinguishing arcs after flashover. The main unit of the power frequency withstand voltage tester features large output capacity while requiring only a small power supply.




    The UHV(L) Power Frequency Series Resonant Test System operates on the principle of series resonance, where the inductive reactance of its reactors is tuned to match the capacitive reactance of the test object (e.g., generator windings), creating resonance at power frequency. This allows the system to generate high output test voltages while drawing minimal input current, making it highly efficient.

    1



    Key advantages include:

    High efficiency and low input power requirement due to resonance;

    Superior output waveform quality with low distortion (THD);

    Automatic arc extinguishing and protection against flashover or breakdown;

    Portable and adaptable design, suitable for on-site testing.


    This system offers a reliable, energy-saving solution for high-voltage diagnostic testing in power generation and transmission applications.



    معلمات المنتج


    المعايير الفنية

    تصنيف الجهد الناتج0 ~ 60kV(AC RMS) and below
    تردد الخرج50 هرتز
    Resonance voltage waveformموجة جيبية نقية، معدل تشويه الموجي ≥1%
    نظام العملFull power conticontrol consolenuous working time of 1min
    quality factor10~40
    أقصى قدرة للاختبار3000 كيلو فولت أمبير فما دون
    إمدادات الطاقة العاملة380V±15%、Power frequency 50Hz


    Serial product configuration(Scope of application(Ac withstand voltage test for generator or motor with outlet voltage of 20kV or below, test frequency: 50Hz))

    موديل المنتجcontrol consoleVoltage regulatorreactor(dry)Excitation transformer(dry)مقسم الفولتنطاق التطبيق
    UHV(L)- 200kVA/25kV30 كيلو واط30kVA(electric)200kVA/25kV Adjustable one30kVA dry30 كيلو فولتhydrodynamo.0.4~1.0μF.(10kV/40MW)
    UHV(L)- 300kVA/50kV60 كيلوواط60kVA(electric)300kVA/50kV Adjustable one60kVA oil-immersed50 كيلو فولتThermal generator.0.27~0.33μF.(20kV/300MW)
    UHV(L)- 600kVA/50kV60 كيلوواط60kVA(electric)200kVA/50kV Adjustable one
    400kVA/50kV Adjustable one
    60kVA oil-immersed50 كيلو فولتThermal generator.0.113~0.45μF.(20kV/600MW)
    UHV(L)- 1200kVA/50kV120 كيلو واط120kVA(induction)200kVA/50kV Fixed two
    800kVA/50kV Adjustable one
    120kVA oil-immersed50 كيلو فولتhydrodynamo.0.6~1.8μF.(20kV/250MW)
    UHV(L)- 2750kVA/55kV300 كيلوواط300kVA(induction)750kVA/55kV Fixed two
    1250kVA/55kV Adjustable one
    120kVA oil-immersed60 كيلو فولتhydrodynamo.1.6~3.3μF.(20kV/770MW)

    Note: the solution can be customized according to the parameters of test objects


    Capacitance of the power system commonly used hydrodynamo reference table

    hydrodynamoRated Capacity(WM)rated voltage(kV)Phase capacitor(μF)
    72.5~8510.50.694
    125~150/1.8~1.9
    30015.751.7~2.5
    40018.02~2.5
    600/2.1~2.5


    Inductance Adjustable Power Frequency AC Resonance Test SystemInductance Adjustable Power Frequency AC Resonance Test System 3Inductance Adjustable Power Frequency AC Resonance Test System 2


    Compared to traditional power frequency test transformers, its advantages are extremely prominent:

    Firstly, the power capacity requirement is low. When testing a 1km 110kV cable, only a 50kW power supply is needed to replace the traditional 2000kVA test transformer, greatly reducing the on-site power supply pressure;

    Secondly, it has strong portability, with lightweight design of core components and a single weight of ≤ 60kg. It is equipped with mobile rollers and specialized lifting structures, making it suitable for transportation and layout in complex environments such as substations and wind power sites;

    Thirdly, it has a wide range of adaptability. By replacing the reactor module and excitation transformer, it can meet the testing needs of various equipment such as 6-500kV cables, 35-500kVGIS, and 10-500kV transformers;

    Fourthly, it has low operating costs, low reactive power loss in resonance state, energy consumption only 1/30-1/100 of traditional equipment, and simple equipment maintenance, with a service life of over 15 years.


    Typical application scenarios

    AC voltage withstand test for hydroelectric generators: for units with a single capacity of 250MW or less, verify the insulation performance of the stator winding.

    High voltage cable withstand voltage test: applicable to the handover and preventive testing of 6kV~500kV cross-linked polyethylene (XLPE) cables.

    Transformer voltage withstand test: Conduct power frequency voltage withstand test on 6kV~500kV transformers to detect insulation defects.

    GIS and SF6 switch test: Verify the insulation strength of gas insulated switchgear equipment.

    Voltage withstand test of other capacitive equipment, such as busbars, bushings, transformers, and other high-voltage equipment.


    FAQ about AC resonant test systems

    1. What is the purpose of series resonance withstand voltage test?  

    Mainly used to detect the insulation performance of power equipment (such as cables, transformers, GIS, etc.) at specific voltages, discover potential insulation defects, and prevent breakdown during operation.

    2. What are the advantages of series resonance test compared to traditional power frequency withstand voltage test?  

    The series resonance test can achieve high test voltage at lower power supply capacity, with lower requirements for the capacitance of the tested object. The electric field generated during resonance is more uniform, and the "impact" on equipment insulation is relatively small.

    3. What safety precautions should be taken when conducting a series resonance test?  

    Strict testing procedures must be followed, including grounding before testing and keeping personnel away during testing. The device itself should also have comprehensive protection functions.

    4. How to choose a suitable series resonant withstand voltage test device based on the test sample?  

    It is necessary to select the appropriate device model based on the capacitance range of the test sample and the required test voltage level, to ensure that the inductance and compensation capability of the device can meet the requirements.









    قد يعجبك ايضا

    • لديك أي أسئلة!

      لا تتردد في الاتصال بنا في أي وقت
      اتصل بنا
    • زورنا

      المبنى رقم 6، مجمع أوبتكس فالي الصناعي البصري الميكانيكي، 84 طريق جاوكسين 5،
      منطقة تطوير التكنولوجيا الجديدة في البحيرة الشرقية، مدينة ووهان، مقاطعة هوبي، الصين

    • ارسل لنا عبر البريد الإلكتروني

      تشياو@hvtest.cc

    • اتصل بنا

      +86-15871365102